Autoclave
| Offer Type: |
|
|---|---|
| Offer Post Time: | 2009-10-21 |
| Expiration Date: | 2010-06-25 |
| Details: |
TMQ. CVK pulse vacuum autoclave is a small-sized automatic high pressure and temperature sterilization equipment which takes pressure steam as medium. It is suitable for sterilizing articles likes dressings, utensils, Class B cavum equipment, medical catheter that used in stomatology, dentistry, surgical, laboratory.
Main feature and characters It is controlled by macro-processor, touch screen, and SCM is adopted as main control. Those makes the system stable and perfect. Temperature, pressure, time, type are shown digitally, and there are states indicator. There are three set sterilize program, 2 test program for the Users. It has BD test program for dressing package steam penetrability inspection. It has vacuum test program, vacuum leakage is less than 0.13Kpa/min. Vacuum pump which imported from Germany is equipped, vacuum degree could reach -0.08MPa(-0.8Bar)after three times pulse. The air in the clearance of dressing, sterilizing bag and dentist hand device can be pumped out to reach perfect steam saturation. Pulse behind vacuum drying system, the vacuum can reach -0.08Mpa (-0.8Bar), and the residue humidity of instrument after drying will not exceed 0.2%. Automatic electron safety lock ensures the door be locked when there's automatic warning, faults and no power. 0.22 ¦Ì m bacterium air filter of air after vacuum, re-pollution can be avoided. Faults could be inspected automatically, and faults code could be displayed digitally. Built-in water tank, pure water and dirty water could be separated. Printer could be equipped according to users requirements. Buzzer gives alarm when all the cycles are ended. Safety device The system will auto cut off power when temperature over the rated temperature. Door safety device: Electric lock makes the sterilization could be run under conditions of the door is closed correctly, if the chamber ahs pressure the door can not be opened. Lower water level alarm device: When water level in the tank is Lower than required, the power will be cut off automatically, Meanwhile alarm signals will be sent. When chamber pressure is over rated value the safety valve could be opened automatically. Electron safety device: The DC control loop with over pressure Protection, the AC loop has breaker. Technique Parameters Design pressure: -0.1 ~ 0.26MPa Rated work pressure: 0.23Mpa Limit vacuum degree: -0.08MPa Pressure control precision: 1KPa Sterilization temperature: 105 ~ 136 degree Temperature control precision0.1 degree Maximum temperature: 136 degree Temperature uniform: ¡Ü0.5degree Chamber material: Stainless steel SUS304, 3 pieces trays made of aluminum. |
Most Popular
-

Autoclave - 17L Autoclave - 17L 1. New type of separte steam ... -

Level Switches For Steam Autoclave The stainless steel float level switches is ... -

Autoclave (Talble-Top Sterilizer Standard) Introduction: 1. Several built-in adjustable ...
-

Steam Sterilizer (3PV-23L B CLASS) STEAM STERILIZER(3PV-23L B CLASS) Three times ... -

Water Ionizer (618JY) 1)Upgradable programe with NEC micro-control ... -

ET Indicator Tape for Sterilization We are produce EO Gas Indicator Tape for ...
-

Ozone Generator with Ionizer and Remote Control 250mg/hour Negative ion>=3*10^6/CC Product ... -

Autoclave - Class N - TMQ. C-3250 45L Main properties: PC control and touch screen ... -

SYG24L Portable SS Steam Sterilizer SYG24L Portable SS Steam Sterilizer Volume of ...
-

Water Distiling Apparatus (WS10L) The pure distilled water is one of the most ... -

Desk-Top Type Timing Electric Boiling Sterilizer (YXF-420) Type YXF-420 Technical Data: 1. Reted ... -

Portable Sterilizer 1. This disinfection device has two designs: The ...
-

Vacuum Autoclave Main Properties: Our autoclave has three ... -

Sterilization Main Product: Air sterilizer have purple ... -

Fruit and Vegetable Washer GL-3188A Agriculture chemical detoxification for fruit and ...
Related Searches |
Inquiry Basket (




